*********************************
There is now a CONTENT FREEZE for Mercury while we switch to a new platform. It began on Friday, March 10 at 6pm and will end on Wednesday, March 15 at noon. No new content can be created during this time, but all material in the system as of the beginning of the freeze will be migrated to the new platform, including users and groups. Functionally the new site is identical to the old one. webteam@gatech.edu
*********************************
THE SCHOOL OF MATERIALS SCIENCE AND ENGINEERING
GEORGIA INSTITUTE OF TECHNOLOGY
Under the provisions of the regulations for the degree
DOCTOR OF PHILOSOPHY
on Wednesday, April 21, 2021
3:00 PM
via
Webex Video Conferencing
https://gatech.webex.com/gatech/j.php?MTID=m69b676eb682fc7cc0660550e464b775d
Meeting Number: 160 423 8761
Password: EB
will be held the
DISSERTATION DEFENSE
for
Eleanor Brightbill
"Optimization of Surface-Protein Interactions for Next Generation Biosensors"
Committee Members:
Prof. Eric Vogel, Advisor, MSE
Prof. Valeria Milam, MSE
Prof. Vladimir Tsukruk, MSE
Prof. Ravi Kane, ChBE
Craig Nies, Ph.D., AVX Corporation
Abstract:
Currently, diagnosis for serological diseases such as Ebola, HIV, and Lyme disease relies on Enzyme-linked Immunosorbent Assays (ELISAs), which require centralized laboratories and several-day timescales to complete. However, emerging technologies such as potentiometric and electrochemical impedance biosensing can be developed into portable, label-free, point-of-care devices that require only hour timescales. Specifically, potentiometric sensing platforms can be miniaturized through cost-effective microfabrication, lend themselves to multiplexed and parallel sensing, and are easily integrated with other electronics.
Despite the promise of these new label free technologies, device reliability inhibits commercialization and adoption. This work focuses on improving potentiometric sensing, primarily through understanding erroneous behavior at the sensor-solution interface. During biomolecular sensing, biomolecules in solution interact with the sensor surface. Ideally, protein recognition mechanisms are leveraged to allow only target proteins to attach to the surface, imparting signal selectivity. However, unwanted protein interactions with sensor surfaces cause signal instability and increase false-positive rates. Although commonly used to functionalize the sensing surface, carboxyl-terminated thiol self-assembled monolayers (COOH-SAMs) can have large defect densities, which in turn leads to large non-selective adsorption of proteins to hydrophobic surfaces exposed by these defects. A procedure is developed where the surface of COOH-SAMs is treated before functionalization to improve the reliability and quality of receptor attachment to the sensor surface. In this method, a preblocking protein orthogonal to the immunological system of interest is used to cover hydrophobic, non-selective sites on the sensor surface while still leaving carboxylic acid headgroups available for covalent functionalization. This methodology is advantageous when compared to standard blocking, where the receptor protein must be attached to the sensor prior to the blocking step. With traditional postblocking, non-selective adsorption and degradation of the receptor protein itself can occur, and the storage stability of the receptor must be considered since the sensor cannot be functionalized after blocking. Additionally, COOH-SAMs oxidize when exposed to ambient conditions. The impact of this degradation of sensing, as well as methods to prevent degradation, are explored.
Beyond SAM-based sensors, there has been significant interest in biomedical applications of 2D materials, including potentiometric sensing. The inert basal plane of certain 2D materials, such as graphene, could lead to larger biosensing signals due to a decrease in surface pH response. However, there is conflicting literature as to what extent interaction from the substrate are transmitted through a 2D monolayer, and the subsequent effect on biomolecule interactions are unknown. Therefore, the degree to which the substrate influences graphene-protein interactions is explored.
The work presented in this thesis demonstrates initial steps towards reliable control over sensor-solution interfaces. Despite the current challenges facing label-free, portable biosensors, the work presented here provides a step towards reliable biosensing.