MS Defense by Jordan Rehwaldt

*********************************
There is now a CONTENT FREEZE for Mercury while we switch to a new platform. It began on Friday, March 10 at 6pm and will end on Wednesday, March 15 at noon. No new content can be created during this time, but all material in the system as of the beginning of the freeze will be migrated to the new platform, including users and groups. Functionally the new site is identical to the old one. webteam@gatech.edu
*********************************

Event Details
  • Date/Time:
    • Monday July 16, 2018 - Tuesday July 17, 2018
      1:00 pm - 2:59 pm
  • Location: U.A. Whitaker Building - Room 3115 (McIntire Conference Room)
  • Phone:
  • URL:
  • Email:
  • Fee(s):
    N/A
  • Extras:
Contact
No contact information submitted.
Summaries

Summary Sentence: DEVELOPMENT OF A DEVICE FOR SUBCONJUNCTIVAL DRUG DELIVERY

Full Summary: No summary paragraph submitted.

Jordan Rehwaldt

BioE MS Thesis Presentation

 

Date: Monday, July 16th, 2018

Time: 1:00 PM

Location: U.A. Whitaker Building - Room 3115 (McIntire Conference Room)

 

Advisor:

C. Ross Ethier, PhD – Department of Biomedical Engineering, Georgia Institute of Technology

 

Committee:

Hans E. Grossniklaus, MD – Department of Ophthalmology, Emory University

Frank L. Hammond III, PhD – Department of Mechanical Engineering, Georgia Institute of Technology

 

 

DEVELOPMENT OF A DEVICE FOR SUBCONJUNCTIVAL DRUG DELIVERY

Subconjunctival (SC) injections have been widely used by ophthalmologists to locally administer various therapeutic agents to the eye (e.g., steroids, antibiotics, and anesthetics). Periocular delivery methods are often more effective than commonly prescribed topical eye drops, improving drug pharmacokinetics and circumventing patient noncompliance. However, the practice of SC delivery is limited by current techniques, which are based on century-old technology and require surgically-trained experts.

The demand for SC injections will rapidly grow in the future due to increasing disease incidence, an aging population, and the imminent approvals of sustained release formulations. To meet this clinical need, this work focuses on the development of a device for SC drug delivery that can be used by eye care providers of only moderate skill and training. Specifically, this thesis comprises the: (i) conception of an aspiration-based SC injection device; (ii) development of a bench testing setup, including novel measures of device performance; and (iii) evaluation and optimization of said device through ex vivo testing in enucleated rabbit and porcine eyes.

Additional Information

In Campus Calendar
No
Groups

Graduate Studies

Invited Audience
Public, Graduate students, Undergraduate students
Categories
Other/Miscellaneous
Keywords
ms defense
Status
  • Created By: Tatianna Richardson
  • Workflow Status: Published
  • Created On: Jul 3, 2018 - 8:35am
  • Last Updated: Jul 3, 2018 - 8:35am