*********************************
There is now a CONTENT FREEZE for Mercury while we switch to a new platform. It began on Friday, March 10 at 6pm and will end on Wednesday, March 15 at noon. No new content can be created during this time, but all material in the system as of the beginning of the freeze will be migrated to the new platform, including users and groups. Functionally the new site is identical to the old one. webteam@gatech.edu
*********************************
Title: Gait Optimization with a Real-time Closed-loop Artificial Sensory Feedback
Committee:
Dr. Stephen DeWeerth, ECE, Chair , Advisor
Dr. Boris Prilutsky, AP, Co-Advisor
Dr. Robert Butera, ECE
Dr. Young-Hui Chang, AP
Dr. Martha Grover, ChBE
Dr. Michel Lemay, Temple University
Abstract:
ndividuals with unilateral lower limb musculoskeletal and neurological conditions, including prosthetic users, experience asymmetric walking. It may result in undesirable compensations by the body and secondary conditions (osteoarthritis, low back pain, etc.). Asymmetric prosthetic walking is partially caused by deficits in motion-dependent feedback from and active control of the prosthetic limb. My goal was to develop a real-time closed-loop control system for a sensing, bone-anchored transtibial prosthesis interfaced with residual peripheral nerves and muscles. The prosthesis and control system would allow users to sense ground contact during walking and control the prosthetic ankle using natural motor commands to automatically correct asymmetries and instability of walking. To inform the design of the prosthesis and control system, I investigated in walking cats the effects of manipulating tactile sensory feedback from paw pads (by anesthesia and electrical stimulation of a sensory nerve) and stretch-dependent feedback from thigh muscles (by varying treadmill speed and by muscle self-reinnervation) on symmetry and stability of walking. I found that removal of tactile and muscle length-dependent feedback resulted in profound changes in symmetry and stability of walking. In addition, electrical stimulation of the distal tibial nerve, innervating paw pads, during the stance phase of walking substantially reduced and sometimes reversed effects of sensory feedback removal. I then demonstrated that a real-time closed-loop gait control system could control step length symmetry of walking cats by stimulation of the distal tibial nerve. This system could be used for correcting asymmetries during walking in people with sensorimotor deficits. I also developed a prototype of a sensing transtibial prosthesis with an ankle joint controlled by activity of residual muscles. The results of this study provide new insights into the role of sensory feedback in control of locomotion and offer new engineering solutions for bone-anchored, limb neuro-prostheses and for improving pathological gait.