There is now a CONTENT FREEZE for Mercury while we switch to a new platform. It began on Friday, March 10 at 6pm and will end on Wednesday, March 15 at noon. No new content can be created during this time, but all material in the system as of the beginning of the freeze will be migrated to the new platform, including users and groups. Functionally the new site is identical to the old one. webteam@gatech.edu
*********************************

Event Details
  • Date/Time:
    • Tuesday March 13, 2012 - Wednesday March 14, 2012
      1:00 pm - 3:59 pm
  • Location: BME Building, Conference Room 2100
  • Phone:
  • URL:
  • Email:
  • Fee(s):
    N/A
  • Extras:
Contact
No contact information submitted.
Summaries

Summary Sentence: Design and Evaluation of a Prosthetic Anterior Cruciate Ligament Replacement Medical Device

Full Summary: Design and Evaluation of a Prosthetic Anterior Cruciate Ligament Replacement Medical Device

David Ku, M.D., Ph.D., Co-Advisor
Mohammed Cherkaoui, Ph.D., Co-Advisor
Dr. Robert E. Guldberg, Ph.D.
Dr. Rudolph L. Gleason, Ph.D.
Dr. Laurent Corte, Ph.D.

Rupture of the anterior cruciate ligament (ACL) is a relatively common sports-related injury for which the current treatment is reconstruction with an autograft or allograft.  Drawbacks associated with each of the current options would make a prosthetic alternative advantageous, however, artificial ligaments are not widely used, having failed due to lack of biocompatibility and mechanical insufficiencies.  To develop the next-generation prosthetic ACL, design control principles were applied including specification of comprehensive design inputs, risk analysis, and verification testing.  A design was proposed utilizing polyvinyl alcohol and ultrahigh molecular weight polyethylene, selected for good biocompatibility and mechanical strength and stiffness suitable for ACL replacement.  A biomimetic fibrous rope pattern was designed for the intra-articular ligament section of the prosthetic that produced a close match the static tensile behavior of the native ACL and which also demonstrated good resistance to fatigue and creep.  A calcium phosphate coating was recommended for the sections of the device lying within the bone tunnel to increase the rate of osseointegration.  The proposed design was then evaluated in a computational simulation to assess functional restoration and the effects of installation parameters such as tension and tunnel orientation on knee kinematics.  The encouraging results of preclinical verification testing support further in vivo evaluation of the proposed design.

Additional Information

In Campus Calendar
No
Groups

Bioengineering Graduate Program

Invited Audience
No audiences were selected.
Categories
Other/Miscellaneous
Keywords
bioengineering
Status
  • Created By: Chris Ruffin
  • Workflow Status: Published
  • Created On: Feb 24, 2012 - 6:01am
  • Last Updated: Oct 7, 2016 - 9:58pm